Commit 29a9ac64 authored by Daniel Matyas's avatar Daniel Matyas Committed by Guenter Roeck
Browse files

hwmon: (max31827) Add custom attribute for resolution



Added custom channel-specific (temp1) attribute for resolution. The wait
time for a conversion in one-shot mode (enable = 0) depends on the
resolution.

When resolution is 12-bit, the conversion time is 140ms, but the minimum
update_interval is 125ms. Handled this problem by waiting an additional
15ms (125ms + 15ms = 140ms).

Added 'mask' parameter to the shutdown_write() function. Now it can
either write or update bits, depending on the value of mask. This is
needed, because for alarms a write is necessary, but for resolution only
the resolution bits should be updated.

Signed-off-by: default avatarDaniel Matyas <daniel.matyas@analog.com>
Link: https://lore.kernel.org/r/20231031182158.124608-5-daniel.matyas@analog.com


Signed-off-by: default avatarGuenter Roeck <linux@roeck-us.net>
parent 64176bde