tools/power turbostat: Avoid probing the same perf counters
For the RAPL package energy status counter, Intel and AMD share the same perf_subsys and perf_name, but with different MSR addresses. Both rapl_counter_arch_infos[0] and rapl_counter_arch_infos[1] are introduced to describe this counter for different Vendors. As a result, the perf counter is probed twice, and causes a failure in in get_rapl_counters() because expected_read_size and actual_read_size don't match. Fix the problem by skipping the already probed counter. Note, this is not a perfect fix. For example, if different vendors/platforms use the same MSR value for different purpose, the code can be fooled when it probes a rapl_counter_arch_infos[] entry that does not belong to the running Vendor/Platform. In a long run, better to put rapl_counter_arch_infos[] into the platform_features so that this becomes Vendor/Platform specific. Signed-off-by:Zhang Rui <rui.zhang@intel.com> Signed-off-by:
Len Brown <len.brown@intel.com>